首页 | 官方网站   微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   81篇
  免费   2篇
工业技术   83篇
  2023年   1篇
  2022年   3篇
  2021年   5篇
  2019年   2篇
  2018年   2篇
  2017年   2篇
  2016年   1篇
  2013年   4篇
  2012年   6篇
  2011年   6篇
  2010年   2篇
  2009年   11篇
  2008年   6篇
  2007年   1篇
  2006年   3篇
  2005年   5篇
  2004年   5篇
  2003年   1篇
  2002年   3篇
  2001年   3篇
  2000年   2篇
  1999年   2篇
  1997年   1篇
  1990年   3篇
  1984年   1篇
  1976年   2篇
排序方式: 共有83条查询结果,搜索用时 78 毫秒
11.
Examined systematically the sample sizes necessary to provide adequate power in validation studies under various conditions of range restriction and criterion unreliability. For purposes of brevity, the examination was restricted to the validity parameter values (i.e., true validities) of .35 and .50. Results demonstrate that sample sizes required to produce adequate power in empirical validation studies are substantially larger than has typically been assumed. This finding leads to the conclusion that, from the viewpoint of sample-size requirements, criterion-related validity studies are "technically feasible" much less frequently than is commonly assumed. It is also shown that the "situational specificity" of employment test validities may be in large part a consequence of excessive faith in small-sample analyses, that is, belief in "the law of small numbers." (16 ref) (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   
12.
In the present research work, the preparation and characterization of bioactive glass-ceramic scaffolds for bone substitutes are described. The scaffolds were prepared by starch consolidation of bioactive glass powders belonging to the SiO2-Na2O-CaO-MgO system using three different organic starches (corn, potatoes and rice) as reported in a previous screening process [1]. The scaffolds, characterized by scanning electron microscopy, showed a porous structure with highly interconnected pores. The pores sizes assessed by mercury intrusion porosimetry put in evidence the presence of pores of 50–100 μm. The structure of the scaffolds was investigated by X-ray diffraction and revealed the glass-ceramic nature of the obtained material. The mechanical properties of the scaffolds were evaluated by means of compressive tests on cubic samples and the obtained results demonstrated their good mechanical strength. The in vitro bioactivity of the scaffolds was tested by soaking them in a simulated body fluid (SBF) and by subsequently characterizing the soaked surfaces by SEM, EDS and X-ray diffraction. Good in vitro bioactivity was found for the starting glass and for the obtained scaffolds. Moreover, the scaffold bioresorption, tested by measuring the samples weight loss in SBF at different periods of time, showed a partial resorption of the scaffolds. Cell culture testing of the three different scaffolds indicated no differences in cell number and in alkaline phosphatase activity; the morphology of the osteoblasts showed good spreading, comparable to bulk material which was used as the control.  相似文献   
13.
Alumina and Ti6Al4V alloys are widely used for orthopedics and dental applications due to their good mechanical properties and biocompatibility. Unfortunately they can not provide a satisfactory osteointegration when implanted. In fact, both alumina and Ti6Al4V are not bioactive and thus they can only guarantee a morphological fixation with the surrounding tissues without a suitable chemical anchorage. Aiming to impart bioactive properties to these materials a coating can be proposed. At this purpose, a bioactive glass belonging to the SiO2-CaO-K2O system was selected and prepared. This glass, named SCK, possess a thermal expansion coefficient matching with the alumina (8.5× 10− 6/ C) and Ti6Al4V (9 × 10− 6/C) ones and thus is a good candidate to produce coatings on both of them. Simple and low-cost enameling and glazing techniques were used to realize the coatings. Structural, morphological and compositional characterizations of the coatings were carried out by means of X-ray diffraction, optical and scanning microscopy and compositional analyses. The in vitro properties of the coatings were investigated by soaking them in a simulated body fluid (SBF) in order to study the precipitation, on their surfaces, of a biologically active layer of hydroxylapatite (HAp).  相似文献   
14.
Bioactive glasses exhibit the unique ability of bone bonding, thus creating a stable interface by stimulating bone cells toward mechanisms of regeneration and self-repair activated by ionic dissolution products. Therefore, 3D glass-derived scaffolds can be considered ideal porous templates to be used in bone tissue engineering strategies and regenerative medicine. This review provides a comprehensive overview of all technological aspects relevant to the fabrication of bioactive glass scaffolds, including the fundamentals of materials processing, a summary of the conventional porogen, and template-based methods and of recent additive manufacturing technologies, which are promising for large-scale production of highly reproducible and reliable implants suitable for a wide range of clinical applications.  相似文献   
15.
Advanced bearing materials for future military and commercial gas turbines are required to operate at high speeds, high temperature, and higher thrust loads. At elevated operating conditions, the bearing and gear materials must be able to operate with ultrathin oil films without suffering detrimental effects of adhesive wear. The development of materials with rolling-element fatigue and corrosion resistance properties without deterioration in adhesive wear attributes is a significant challenge. To meet those performance requirements, the forerunner, martensitic stainless steel Pyrowear 675 (AMS 5930), has been in development for aerospace bearing and gear applications. This article addresses the adhesive wear performance of three variants of Pyrowear 675 with silicon nitride ball material simulating a hybrid bearing evaluated using a WAM8 machine. Baseline testing was conducted using conventional bearing steel AISI M-50. Adhesive wear testing was conducted at a temperature of 200°C and at different contact slips (15, 30, 50, and 70%) and entraining velocities (1.3 to 10.2 m/s). Posttest specimens were analyzed by scanning electron microscopy (SEM) and auger electron spectroscopy (AES). All the hybrid material pairs demonstrated very good adhesive wear performance compared to the baseline AISI M-50–AISI M-50 pair.  相似文献   
16.
Highly bioactive scaffolds for tissue engineering were synthesized using a glass belonging to the SiO2-CaO-K2O (SCK) system. The glass SCK was prepared by a traditional melting-quenching route and its bioactivity was assessed by in vitro tests in a simulated body fluid (SBF). The glass was ground and sieved to obtain powders of specific size that were subsequently mixed with polyethylene particles of two different dimensions. The powders were then uniaxially pressed to obtain a crack free green compact that was thermally treated to remove the organic component and to sinter the inorganic phase. The obtained biomaterial was characterised by means of X-ray Diffraction, SEM equipped with EDS, mercury intrusion porosimetry, density measurements, image analysis, mechanical tests and in vitro evaluations. A glass-ceramic macroporous scaffold with a homogenously distributed and highly interconnected porosity was obtained. The amount and size of the introduced porosity could be tailored using various amounts of polyethylene powders of different size.  相似文献   
17.
18.
The current study investigated hormonal and ovarian changes during physiological reproductive aging in Sarda ewes. In a first experiment, follicular and corpus luteum dynamics were compared during an induced oestrus cycle in aged (12-14 years) and young adult ewes (4-5 years). Oestrus cycle characteristics did not differ between the two experimental groups. However, follicular function during the follicular phase showed significant alterations in aged ewes, as determined by a lack of dominance effect and by lower mean values of circulating oestradiol (E(2)) and inhibin levels, compared with young adult ewes. In a second experiment, differences in follicle growth, hormonal milieu and oocyte quality in response to exogenous FSH administration were assessed in aged and adult ewes. No differences were recorded in ovarian response to FSH treatment between young adult and aged ewes, as evaluated by ultrasonographic data and circulating concentrations of LH, E(2) and inhibin-A. Although the total number of recovered oocytes was similar in the two age groups, the number of good quality oocytes selected for IVM was significantly lower in aged ewes compared with adult ones. Thereafter, no differences were recorded in cleavage rates, total blastocyst output, embryo developmental kinetic and quality between aged and adult groups. In conclusion, this study demonstrated that reproductive aging in sheep is associated with impaired follicle functionality and an increase in the proportion of oocytes showing morphological abnormalities. However interestingly, oocyte developmental competence in vitro and embryo cryotolerance were not affected by the aging process, when only good quality oocytes were chosen.  相似文献   
19.
20.
This study aimed to fabricate and investigate the structure, mechanical properties and bioactivity of three-dimensional (3-D) glass–ceramic scaffolds for bone tissue engineering. The scaffold material was a fluoroapatite-containing glass–ceramic synthesized by a melting–quenching route. Glass–ceramic powders were mixed with polyethylene particles acting as pore formers; the blend was pressed to obtain “green” compacts that were thermally treated to remove the organic phase and to sinter the inorganic one. The structure and morphology of the resulting scaffolds were characterized by X-ray diffraction, scanning electron microscopy, density measurements and capillarity tests. Crushing tests were carried out to investigate the mechanical properties of the scaffolds. The in vitro bioactivity was assessed by soaking the scaffolds in simulated body fluid for different time frames and by analyzing the modifications that occurred on the sample surface. The scaffolds had an interconnected macroporous structure with pores up to 50% vol. and they showed an orthotropic mechanical behaviour and strength well above 20 MPa. In addition, in vitro tests put into evidence the excellent bioactivity of the material. Therefore, the prepared scaffolds can be used in bone reconstructive surgery as effective load-bearing grafts thanks to their ease of tailoring, bioactive properties and high mechanical strength.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23

京公网安备 11010802026262号